drinking water inspectorate logo - click here to go home

Chief Inspector's Report 2002


20 Tendring Hundred Water Services Limited

Overall Water Quality supplied by Tendring Hundred Water Services Limited in 2002
  • A total of 3,739 tests were carried out on samples taken by Tendring Hundred Water Services Limited in 2002.
  • Of these tests, 99.84% complied with the Regulations.

Tendring Hundred-MAP

Company Information
Amount of Water Supplied: 30 Ml/d
Consumers Supplied: 145,000
Areas of Supply: Tendring Peninsula of Essex
Water Composition: 20% from rivers and reservoirs
  80% from boreholes and aquifers
Treatment Works: 2 (3 compliance monitoring points)
Service Reservoirs: 8
Km of Mains: 910
Water Supply Zones: 4

Water Quality at Treatment Works, in Service Reservoirs and in Water Supply Zones

To be wholesome, water must comply with the standards for the parameters set out in the Water Supply (Water Quality) Regulations 1989. In 2002, the Company carried out a total of 3,739 tests on samples taken at water treatment works, from service reservoirs and in water supply zones and of these, 99.84% complied with the relevant water quality standards set down in the Regulations. A list of the parameters, the relevant standards and their significance can be found at the beginning of this section.

Water Quality leaving Treatment works

 
2002
2001
2000
Number of water treatment works
3
3
3
COLIFORMS
Total number of tests
386
373
631
- number containing coliforms
1
0
0
- % containing coliforms
0.26%
0.00%
0.00%
Treatment works with coliforms detected
1
0
0
- % of all works with coliforms detected
33.33%
0.00%
0.00%
FAECAL COLIFORMS
Total number of tests
386
373
631
- number containing faecal coliforms
1
0
0
- % containing faecal coliforms
0.26%
0.00%
0.00%
Treatment works with faecal coliforms detected
1
0
0
- % of all works with faecal coliforms detected
33.33%
0.00%
0.00%

Failures of the coliform and faecal coliform standards at one works in 2002 were considered trivial. Differences over the last three years in the number of treatment works, and in the number of tests carried out on samples from treatment works, in which coliforms or faecal coliforms were detected were not considered significant.

In 2002, the Company were not required to take any regulatory samples for Cryptosporidium at any of its sites.

Water Quality in Service Reservoirs

 
2002
2001
2000
Number of service reservoirs
8
8
8
COLIFORMS
Total number of tests
410
448
449
- number containing coliforms
1
0
0
- % containing coliforms
0.24%
0.00%
0.00%
Service reservoirs with coliforms detected
1
0
0
Service reservoirs with coliforms detected
0
0
0
in more than 5% of tests
- % of all service reservoirs with coliforms detected
0.00%
0.00%
0.00%
FAECAL COLIFORMS
Total number of tests
410
448
449
- number containing faecal coliforms
1
0
0
- % containing faecal coliforms
0.24%
0.00%
0.00%
Service reservoirs with faecal coliforms detected
1
0
0
- % of all service reservoirs with faecal coliforms detected
12.50%
0.00%
0.00%

There were no failures of the coliform standard at any of the service reservoirs. The detection of faecal coliforms at one service reservoir was considered trivial. Differences over the last three years in the number of service reservoirs, and in the number of tests carried out on samples from service reservoirs, in which coliforms or faecal coliforms were detected were not considered significant.

Water Quality in Water Supply Zones

The table below shows the data for the key parameters and any other parameters where there was a failure of the standard. All other parameters were fully compliant.

Parameter
Total
number
of tests
Tests not meeting
the prescribed
concentration
or value
Number of
failures
covered by
Undertakings
Number of zones
not complying with
the standards
No
%
2002
2001
2000
Coliforms
377
1
0.27
0
0
0
0
Faecal coliforms
377
0
0.00
0
0
0
1
Colour
36
0
0.00
0
0
0
0
Turbidity
54
0
0.00
0
0
0
1
Odour
36
0
0.00
0
0
0
0
Taste
36
0
0.00
0
0
0
0
Hydrogen ion
41
0
0.00
0
0
0
0
Nitrate
37
0
0.00
0
0
0
0
Nitrite
36
0
0.00
0
0
0
1
Aluminium
36
0
0.00
0
0
0
0
Iron
118
1
0.85
0
1
1
0
Manganese
54
0
0.00
0
0
0
1
Lead
16
0
0.00
0
0
0
0
PAH
16
0
0.00
0
0
0
0
Trihalomethanes
32
0
0.00
0
0
0
0
Total pesticides
16
0
0.00
0
0
0
0
Other pesticides
320
0
0.00
0
0
0
0
All others
509
0
0.00
0
0
0
0
TOTAL
2,147
2
0.09%
0
4 zones in 2000, 2001 and 2002

The New Regulations

In 2002, the Company carried out monitoring for the six new parametric values set down in the new Water Supply (Water Quality) Regulations 2000. These Regulations come into force on 25 December 2003. The results are shown in the table below.

Parameter
Total number
of tests
New standard
Tests not meeting
the new standard
Benzene
25
1.0 µg/l
0
Bromate
23
10.0 µg/l
1
1,2 dichloroethane
24
3.0 µg/l
0
Nitrite (ex-water treatment works)
56
0.1 mg/l
0
Clostridium perfringens
26
0/100 ml
0
Enterococci
30
0/100 ml
0

Compliance data for 2002 has also been analysed against the revised standards and the results are shown in the following table.

Parameter
Total
number
or tests
Current
Standard
Number of
tests not
meeting current
standard
Revised
Standard
Number of
tests not
meeting revised
standard
Antimony
4
10.0 µg/l
0
5.0 µg/l
0
Arsenic
4
50.0 µg/l
0
10.0 µg/l
0
Boron
4
2.0 mg/l
0
1.0 mg/l
0
Copper
16
3.0 mg/l
0
2.0 mg/l
0
Lead
16
50.0 µg/l
0
25.0 µg/l1
0
 
10.0 µg/l2
Nickel
5
50.0 µg/l
0
20.0 µg/l
0
Nitrite (at consumers' taps)
36
0.1 mg/l
0
0.5 mg/l
0
PAH
16
0.2 µg/l
0
0.1 µg/l
0
Tetrachloroethene
16
30.0 µg/l
0
}
0
10.0 µg/l
0
Trichloroethene
16
10.0 µg/l

Details of the new and revised standards, and the reasons for the revisions where applicable, can be found in chapter J "New Regulations and Associated Programmes of Work".

1 From 25.12.03

2 From 25.12.13

Company Audit and Inspection

The Company was inspected or audited by the Inspectorate or its appointed consultants on a number of occasions during 2002. Where relevant, report summaries are available in the 'Business and Technical' section of the Inspectorate's web site under 'Audit and Inspection'.

Audit or Inspection Date
Review of distribution system undertaking August 2002
Inspection of one water treatment works and one service reservoir November 2002
Audit of sampling arrangements November 2002
Audit of response to selected consumer complaints November 2002
Audit trails of five test results December 2002
Review of plumbosolvency treatment and control programmes of work for lead December 2002

A number of recommendations were made in respect of action required to avoid the risk of a breach of a regulatory duty. These recommendations were in relation to the sample audit trails.

Incidents

The Inspectorate regarded none of the events notified during 2002 by the Company as incidents. For further details on the classification of incidents, see chapter C "Events affecting Water Quality" in Part 3.

Enforcement Action

No enforcement action was considered for the Company as a result of the Inspectorate's activities during 2002.

Undertakings and other Improvement Programmes

Water treatment works and service reservoirs

No improvement programmes were due for completion during 2002.

Distribution

Surveys undertaken in connection with the Company's distribution system undertaking have demonstrated that no mains renovation is justified.

Lead

The Company has a Regulation 41 programme of work to meet the revised standard for lead set down in the new Water Supply (Water Quality) Regulations 2000, which will come into force on 25 December 2003. Progress with the delivery of the programme is monitored by the Inspectorate and has been satisfactory. 


A-Z index press releases Links Site Home Contact Us search

Drinking Water Inspectorate

Ashdown House, 123 Victoria Street, London, SW1E 6DE
Telephone : 020 7944 5956


Department for Enviroment,
Food & Rural Affairs (DEFRA)

The National Assembly for Wales /
Cynulliad Cenedlaethol Cymru


Last updated July 2003

Web site terms
© Crown copyright 2002


DWI strives to ensure that the information on this website is set out in an accessible and understandable manner.
We welcome any comments about our website, including suggestions for additional topics that might be useful to our customers.